Products
----------------------------------------
-
Wall Mounted
9 - 12,000 BTU
9 - 15,000 BTU RLS
9 - 15,000 BTU
- RLS2
18 - 30,000 BTU
H/P
18 - 36,000 BTU Cooling
----------------------------------------
- Hybrid Flex
Inverter
----------------------------------------
-
Cassette
----------------------------------------
-
Large
Ceiling
----------------------------------------
-
Universal Floor / Ceiling
----------------------------------------
 |

|
Products
>
Wall Mounted 9 - 12,000 BTU |
 |
Wall Mounted
 |
|

Indoor Unit
Systems: 9R2, 12R2 |
Indoor
Unit
ASU9RLF, 12RLF |

Outdoor Unit
AOU9RLFW |
Strong, quiet and efficient DC motors are used both indoors and
outdoors. High performance fan blades, condensers and evaporators
combined with variable speed inverter-driven compressors make for
unmatched performance. Variable speed compressors automatically adjust
to
fluctuating room capacity requirements.
This category of equipment is ideal for smaller spaces where spot
cooling or heating is required. Systems 9R2 and 12R2 are 115 volt
heat pumps, making residential applications including sunrooms and
additions much easier.
Stylish, slim and elegant, these popular wall mounted units
are designed for single rooms. Indoor units have a clean, aesthetic design and are small but mighty and shorter in
length than competing units, helping them blend into any room. 9RLFW and 12RLFW are
Energy Star qualified
heat pumps,
meaning they save you money on your utility bill and provide both
heating and cooling.
As part of the HFI line of components, indoor units ASU9RLF and ASU12RLF
are compatible with larger multi-zone outdoor units of the
HFI line, meaning less SKUs to stock for distributors. |

Outdoor Unit
AOU12RLFW |

Outdoor Unit
Systems: 9R2, 12R2 |

Ask Fujitsu

Need
Pricing?
Contact
a local contractor. |
 |
|
SYSTEM |
9R2 |
12R2 |
9RLFW |
12RLFW |
|
CAPACITIES: |
|
Cooling
BTU/h |
9,700 |
12,300 |
9,000 |
12,000 |
Outdoor
Design Temp
F° DB/WB |
95/75 |
95/75 |
95/75 |
95/75 |
|
Heating
BTU/h |
9,600 |
12,800 |
12,000 |
16,000 |
Outdoor
Design Temp
F° DB/WB |
47/43 |
47/43 |
47/43 |
47/43 |
|
SEER |
14.3 |
13.7 |
23.0 |
22.0 |
|
EER Clg/Htg |
11.8/13.9 |
11.5/12.9 |
13.8/13.47 |
12.5/12.5 |
|
HSPF |
8.2 |
8.2 |
11.0 |
11.0 |
|
Power Supply
(V) |
115 |
115 |
208-230 |
208-230 |
|
INDOOR
UNIT: |
Noise Level
db (A) Cooling
Hi
Med
Lo
Quiet |
40
36
31
26 |
45
40
34
29 |
37
33
29
25 |
40
36
30
25 |
Noise Level
db (A) Heating
Hi
Med
Lo
Quiet |
38
34
29
25 |
42
37
32
27 |
37
33
29
25 |
40
36
31
25 |
|
Weight
(lbs.) |
21 |
21 |
18 |
18 |
|
OUTDOOR
UNIT: |
|
Max Fuse
Size (A) |
15 |
20 |
15 |
20 |
|
Running
Current Clg (A) Rated |
7.6 |
9.9 |
6.0 |
6.5 |
|
Running
Current Htg (A) Rated |
6.5 |
9.2 |
7.5 |
9.0 |
|
Weight
(lbs.) |
71 |
79 |
71 |
71 |
|
REFRIGERANT PIPING: |
|
Max Ht.
Difference (ft.) |
26 |
26 |
49 |
49 |
Max Total or
Combined
Length (ft.) |
49 |
49 |
66 |
66 |
Discharge
Vapor Line
(O.D.) inches |
1/4 |
1/4 |
1/4 |
1/4 |
|
Suction
(O.D.) inches |
3/8 |
3/8 |
3/8 |
3/8 |
|
|
|
|