Products
----------------------------------------
-
Wall Mounted
9 - 12,000 BTU
9 - 15,000 BTU Hi SEER
9 - 15,000 BTU - RLS2
18 - 30,000 BTU
H/P
18 - 36,000 BTU Cooling
----------------------------------------
- Hybrid Flex Inverter
----------------------------------------
-
Cassette
----------------------------------------
-
Large
Ceiling
----------------------------------------
-
Universal Floor / Ceiling
----------------------------------------
 |

|
Products
>
Wall Mounted 9, 12, 15,000 BTU Hi SEER |
|
 |
Wall Mounted
- NEW!
 |
|
Most Energy Efficient Mini-Split in North
America!

Indoor Unit
Systems: 9RLS2, 12RLS2, 15RLS2
|

Outdoor Unit
Systems: 9RLS2, 12RLS2, 15RLS2 |
As much as half of the energy used in your home goes to heating and
cooling. So making smart decisions about a home’s HVAC system can have a
big effect on utility bills — and comfort. Systems 9RLS2, 12RLS2 and 15RLS2
are the most efficient mini-splits in North America, with Seasonal
Energy Efficiency Ratings of up to 27.2-SEER.
The RLS2 systems are packed with features specifically created to save
you money – like Energy Saving Program, or ESP, a programmable remote
control and inverter technology.
|

Ask
Fujitsu

Need
Pricing?
Contact
a local contractor. |
 |
|
SYSTEM |
9RLS2 |
12RLS2 |
15RLS2 |
|
CAPACITIES: |
|
Cooling
BTU/h |
9,000 |
12,000 |
14,500 |
Outdoor
Design Temp
F° DB/WB |
95/75 |
95/75 |
95/75 |
|
Heating
BTU/h |
12,000 |
16,000 |
18,000 |
Outdoor
Design Temp
F° DB/WB |
47/43 |
47/43 |
47/43 |
|
SEER |
27.2 |
25 |
21.5 |
|
EER Clg/Htg |
16.1/15.0 |
13.8/13.3 |
12.0/13.3 |
|
HSPF |
12.5 |
12.0 |
12.0 |
|
Power Supply
(V) |
208-230 |
208-230 |
208-230 |
|
INDOOR
UNIT: |
Noise Level
db (A) Cooling
Hi
Med
Lo
Quiet |
43
37
32
21 |
43
37
32
21 |
45
40
33
25 |
Noise Level
db (A) Heating
Hi
Med
Lo
Quiet |
43
38
32
21 |
43
38
32
21 |
45
40
34
27 |
|
Weight
(lbs.) |
21 |
21 |
21 |
|
OUTDOOR
UNIT: |
|
Max Fuse
Size (A) |
20 |
20 |
20 |
|
Running
Current Clg (A) Rated |
2.7 |
4.0 |
5.5 |
|
Running
Current Htg (A) Rated |
3.7 |
5.5 |
6.1 |
|
Weight
(lbs.) |
88 |
88 |
88 |
|
REFRIGERANT PIPING: |
|
Max Ht.
Difference (ft.) |
49 |
49 |
49 |
Max Total or
Combined
Length (ft.) |
66 |
66 |
66 |
Discharge
Vapor Line
(O.D.) inches |
1/4 |
1/4 |
1/4 |
|
Suction
(O.D.) inches |
3/8 |
3/8 |