This category of equipment is ideal for smaller spaces where spot cooling or heating is required. Several models in this category are Energy Star qualified, meaning they save you money on your utility bill. Residential applications including sunrooms and additions are made easier with these air conditioners and heat pumps. Do you have a warm spot in your home? Our mini-splits can provide extra cooling capacity for those hard to cool areas. Commercially, their small size makes them ideal for small offices, providing individual temperature control.


  Energy Calculator

Ask Fujitsu

  SYSTEM 9CQ 9RQ 9RLQ 12CQ 12RQ 12RLQ
  CAPACITIES:
  Cooling BTU/h 9,700 9,700 9,000 12,300 12,300 12,000
  Outdoor Design Temp
  F°  DB/WB
95/75 95/75 95/75 95/75 95/75 95/75
  Heating BTU/h - 9,600 12,000 - 12,300 16,000
  Outdoor Design Temp
  F°  DB/WB
- 47/43 47/43 - 47/43 47/43
  SEER 14.3 14.3 21.0 13.5 13.7 21.0
  EER Clg/Htg 11.8 11.8/13.9 13.5/14.5 11.6 11.5/12.9 12.5/12.8
  HSPF - 8.2 11 - 8.2 10.55
  Power Supply (V) 115 115 208-230 115 115 208-230
  INDOOR UNIT:
  Noise Level db (A) Cooling
                             Hi
                             Med
                             Lo
40
36
31
  42
37
31
45
40
35
  43
37
31
  Noise Level db (A) Heating
                             Hi
                             Med
                             Lo
-
 
40
36
31
42
37
30
-
 
45
40
35
42
37
30
  Weight (lbs.) 21 21 21 21 21 21
  OUTDOOR UNIT:
  Max Fuse Size (A) 15 15 20 20 20 20
  Min. Ampacity (A) 12 12 10 15 15 12
  Running Current Clg (A) Rated/Max 7.6 7.6 3.2/6.0 9.8 9.9 4.5/7.0
  Running Current Htg (A) Rated/Max - 6.5 3.9/8.5 - 9.2 5.7/10.0
  Weight (lbs.) 68 71 77 77 79 82
  REFRIGERANT PIPING:
  Max Ht. Difference (ft.) 26 26 49 26 26 49
  Max Total or Combined
  Length (ft.)
49 49 66 49 49 66
  Discharge Vapor Line
  (O.D.) inches
1/4 1/4 1/4 1/4 1/4 1/4
  Suction (O.D.) inches 3/8 3/8 3/8 3/8 3/8 3/8
 